TM 5-4120-386-14
4-24. CONTROL MODULE-Continued.
REMARKS
LOCATION/ITEM
ACTION
Replacement-
Continued
21. Control
Module Harness- j.
Solder wire to appropriate con-
nector pin.
Continued
k. Straighten and clean any bent or
dirty pins on comector plug.
1.
Replace connector plug with leads
if pins are damaged beyond repair.
Reassembly
22. Temperature
a. Attach switch to back plate
using four screws (53), four
Selector
flat washers (55), and four
Switch
nuts (54).
b. Install capillary tube clamp
on capillary tube.
c. Attach capillary tube clamp
(51) to back plate using screw
(48), flat washer (50), lock nut
(49), and spacer (52).
23. Evaporator
a.
Slide switch (13) into front plate
Fan Speed
through backside.
b. Attach switch (13) using lockring
Switch
(16), lockwasher (15), and two
mounting nuts (14).
c. Connect leads and remove tags.
24. Mode
a.
Slide switch (39) into front
plate through backside.
Selector
b. Attach switch (39) using lockwasher
Switch
(41) and mounting nut (40).
c. Install selector knob (11) and
tighten set screw (12).
d. Connect leads and remove tags.
a.
25. Compressor
Slide switch (44) into front plate
through backside.
Circuit
Breaker
b. Attach switch using six screws
(42) and six flat washers (43).
c . Aline middle sections of throw
switch and insert pin.
d. Connect leads and remove tags.
4-53
|