TM 9-4110-241-13
TO 35E9-274-1
4-25. REMOVE/TEST/INSTALL LIGHT ASSEMBLY AND GLOBE.
b. Removal:
WARNING
Disconnect power to power receptacle before beginning this procedure.
(1) Remove screws and gently pull light assembly away from wall.
(2) Tag and disconnect wires to light assembly.
MODELS MDS1600N, TKR-600C
AND TKR-4000C
MODELS AA600PF
AA1200PFA,
AND AA4000PF
Figure 4-19. Light Assembly and Globe
c. Test:
(1) Attach a 125 VAC power source to vapor proof socket.
(2) Use a multimeter to check voltage across socket.
d. Installation:
(1) Connect wires to light assembly and remove wire tags.
(2) Mount socket onto wall using screws.
(3) Reconnect power to power receptacle.
CHANGE 1 4-41
|