Table 2-1. Operator Preventive Maintenance Checks and Services for model F10000RD-Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
3
Before
V-Belts
Inspect the V-belts for frayed edges, cracks,
V-belt is frayed, cracked,
glazing, or hard brittle condition. Inspect for
glazed, or hard and
excessive looseness or slippage. If damaged or
brittle. V-belt is
loose, notify unit maintenance to tighten or
excessively loose or
replace it as necessary.
slipping.
4
Before
Pulleys
Inspect pulleys for cracks, chips, or warpage.
Pulley is cracked,
Inspect for secure mounting to shaft. If damaged
chipped, warped, or
or loose, notify unit maintenance to tighten or
loose on shaft.
replace it as necessary.
5
Before
Fan Drive
Inspect fan drive shaft for cracks, chips, or
Fan drive shaft is
Shaft
warpage. If damaged, notify direct support
cracked, chipped, or
maintenance to replace it as necessary.
warped.
WARNING
The fuel used in this refrigeration unit is
highly explosive. Do not make or use
open flame when performing
maintenance. Flames and explosion
could result in severe personal injury or
death.
6
Before
Fuel Tank
Inspect fuel tank.
a.
Check for cuts, dents, cracks, or leaks.
Fuel tank is cut, cracked,
or leak is found.
b.
Service fuel tank by checking fuel level. If
Fuel level is less than 1/4
level is less than 1/4 tank, top off with fuel
tank.
(27, appendix E) if operating between
5° F (-15° C) and 120° F (49° C) or
(28, appendix E) if operating between
O F (-18 C) and 5° F (-15° C).
2-11
|