TM9 4120-423-14&P
FUSE (F1) AND FUSEHOLDER (XF1)
THIS WORK PACKAGE COVERS:
Inspection of Installed Items
Removal
Installation
Tools and Special Tools
Screwdriver
Wrench
Soldering gun
Knife
Materials/Parts
Fuse
F02A250V6A
FHN20G
Personnel Required
Unit Technician
Equipment Conditions
Top evaporator cover removed (See
Evaporator module cover removed (See
INSPECTION OF INSTALLED ITEMS
1
Push in, turn, and remove the fuse holder cap.
2
Remove fuse.
3
Look at fuse to see if the center element is broken or melted. Replace fuse if found bad.
4
Using multimeter, test fuse for continuity. Replace fuse if no continuity.
0036 00-1
|