EVAPORATOR AIR INTAKE FILTER UNIT MAINTENANCE
THIS WORK PACKAGE COVERS:
Removal, Cleaning, and Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Hose, with running water
Filter-kote or oil (Item 17, WP 0121-00)
Dry cleaning solvent (Item 16, WP 0121-00)
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0118-00)
Equipment Condition
Evaporator inlet louver removed (WP 0020-00).
WARNING
Disconnect air conditioner power input connector.
REMOVAL
Remove air filter (5) from clips (7) and (8) on louver (4).
WARNING
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning solvent. Wash exposed skin thoroughly. Dry
cleaning solvent, P-D-680, used to clean parts, is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open
flame or excessive heat. Flash point of solvent is 100F to 138F (38C to 59C).
0023-00-1