TM 9-4120-425-14&P
EVAPORATOR FAN MOTOR UNIT MAINTENANCE
THIS WORK PACKAGE COVERS:
Test
INITIAL SETUP:
Maintenance Level
Unit Support
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0118-00)
References
Schematic Diagram, WP 0122-00
Equipment Condition
Main power source is disconnected, shut down and cool.
Evaporator air intake louver removed (WP 0020-00).
Junction box assembly partially removed from unit (WP 0035-00).
WARNING
Disconnect air conditioner power.
TEST
1.
Carefully slide out junction box assembly from unit to access terminal board TB2 for testing motor B2. Refer to WP
2.
Using an ohmmeter set on lowest ohms scale, check continuity between black lead and red lead (TB2 terminals 10
& 11) of motor B2. Continuity should be indicated between these leads.
3.
Test continuity between black lead and green lead (ground) of motor B2 (TB2 terminals 10 and ground). Continuity
should NOT be indicated between these leads.
4.
Rotate motor shaft very slowly and check for smooth and quiet operation of shaft. Shaft should rotate smoothly and
should not make grinding or binding noises.
5.
If evaporator motor fails any of the above tests, motor must be replaced. Report motor failure to Direct Support
Maintenance shop for replacement.
END OF TASK
0030-00-1
|