![]() TM 9-4120-428-14
UNIT MAINTENANCE
AIR CONDITIONER, HORIZONTAL, COMPACT
(NSN 4120-01-502-1319)
EVAPORATOR FAN SPEED TOGGLE SWITCH (S2) REMOVAL, INSPECTION, TESTING, REPLACEMENT,
AND INSTALLATION
INITIAL SETUP:
Equipment Condition
Tools
Remove control module (WP 0029 00).
Refrigeration Unit Service Tool Kit, WP 0000 00, Item
1
Materials/Parts
Evaporator Fan Speed Toggle Switch
Self-Locking Screws (3)
A2
A3
A1
B3
B1
B2
5
C3
C1
12
3
C2
4
6
2
11
8
10
9
7
12
1
REMOVAL
1. Remove four machine screws (1) and the pull control cover (2).
2. Loosen the setscrew (3) in the knob (4). Remove knob.
3. Remove three machine screws (5) from the spacer posts (6) and slip the mounting frame (7) off.
4. Tag and disconnect wires from the Evaporator Fan Speed Toggle Switch (8).
5. Remove the nut (9) and washer (10) and pull the Evaporator Fan Speed Toggle Switch (8) from the designation plate
(11).
0031 00-1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |