TM 9-4120-428-14
UNIT MAINTENANCE
AIR CONDITIONER, HORIZONTAL, COMPACT
(NSN 4120-01-502-1319)
COMPRESSOR START RELAY K5 REMOVAL, INSPECTION, TESTING, REPLACEMENT, AND
INSTALLATION
INITIAL SETUP:
Equipment Condition
Tools
Remove Top Panels (WP 0019 00)
Refrigeration Unit Service Tool Kit, WP 0000 00, Item
1
Materials/Parts
Compressor Start Relay
Lock Washer
1
2
WIRE
LEADS
3
2
C
5
1
RELAY DIAGRAM
NOTE
The Compressor Start Relay is installed on all units. The Relay is connected to the start
capacitor on units using WELCO compressors only.
REMOVAL
1. Remove screw (1) and lock washer (2) from the mounting tab and remove the relay (3) from unit.
2. Tag and disconnect all leads.
INSPECTION
Inspect for cracks, bent or missing mounting tab, bent or missing terminals, dents or other obvious defects. Replace
if damaged or defective.