TM 9-4120-430-14
UNIT MAINTENANCE
AIR CONDITIONER, COMPACT, HORIZONTAL
INFORMATION PLATES MAINTENANCE
REMOVAL AND INSTALLATION
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0067 00)
Materials/Parts
Dry Cleaning Solvent (Item 16, WP 0069 00)
Warm soapy water
Personnel Required
One
Equipment Condition
Main power source disconnected
WARNING
Ensure power source is disconnected.
NOTE
Remove and replace only badly damaged, unreadable information plates. Refer to
WP 0002 00 for text on each plate or decal.
REMOVAL
Decals
Using a flathead screwdriver, remove the following decals (see Figure 1):
High pressure charging valve decal (5)
Charging valve access cover (6)
Low pressure charging valve decal (7)
Vent instruction decal (11)
Grounding lug decal (12)
Caution grounding decal (13)
Danger decal (14)
Lift caution decal (15)
Warning decal (16)
Caution (208 or 230) volts decal (18 or 19)
Caution connect ground decal (20)
Plates
Using a 1/8 diameter drill, remove rivets (1 and 2) from the following information plates:
Equipment data plate (3 or 4)
Refrigeration diagram plate (8)
Schematic diagram plate (9 or 10)
Warranty plate (17)