TM 9-4120-430-14
0023 00
CLEANING
WARNING
DRY CLEANING SOLVENT P-D-680
P-D-680 solvent vapors are toxic. Avoid prolonged or repeated breathing of vapors
or solvent contact with skin. Use only with adequate ventilation. Solvent is
flammable and should not be used near open flame. Fire extinguishers should be
readily available when solvent is used.
1. Inspect filter (2). Replace damaged filter and filter media. Clean with warm soapy water or dry cleaning solvent
(Item 16, WP 0069 00). Hose with water in both directions.
2. Replace filters having breaks, tears, excess accumulations of dirt or grease, or other major damage.
3. Lubricate air filter with filter-kote (Item 17, WP 0069 00).
INSTALLATION
1. Install evaporator air intake filter (2) and filter media (3) into evaporator air intake louver (1) by sliding the filter and
filter media into either side of lover casing.
2. Install evaporator air intake louver. (See WP 0019 00.)
END OF WORK PACKAGE