TM 9-4120-430-14
0028 00
3. To remove connector J3 (24, figure 3), remove two screws (22) and two lock nuts (23).
4. Verify wire labels to wire list (WP 0038 00) and desolder and replace connector J3 (24).
5. Secure connector J3 (24) to junction box chassis (4) with two screws (22) and two lock nuts (23).
Transformer (TR) (25, Figure 3)
See WP 0030 00 for maintenance instructions.
Junction Box
1.
Carefully install junction box (2, Figure 2) into the unit housing and secure with seven screws (1).
2.
Position wiring away from blower inlet housing.
3.
Install lower housing plate (4) onto housing and secure with five screws (3).
4.
Connect unit grounding lug (1, figure 4) to unit housing with star washer (4), flat washer (3), and screw (2).
5.
Install evaporator air intake louver (WP 0020 00).
6.
Install remote control module (WP 0026 00).
7.
Install top cover (WP 0018 00).
END OF WORK PACKAGE
0028 00-9/10 blank
|