Click here to make tpub.com your Home Page

Page Title: INSTALLATION HARDWARE MAINTENANCE
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-4120-430-14
UNIT MAINTENANCE
AIR CONDITIONER, COMPACT, HORIZONTAL
INSTALLATION HARDWARE MAINTENANCE
REMOVAL, INSPECTION, AND INSTALLATION
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0067 00)
Personnel Required
Two
Equipment Condition
Main power source is disconnected.
WARNING
Ensure power source is disconnected.
REMOVAL
1.
Remove four screws (1) and flat washers (2) from bottom of air conditioner and enclosure mounting plate (6). See
Figure 1.
2.
Remove four resilient mounts (3), four elastomeric tubes (5) and four spacers (4) from bottom of enclosure
mounting plate (6).
3.
Remove air conditioner from atop of four remaining resilient mounts (3) and the enclosure mounting plate (6).
4.
Remove the remaining four resilient mounts (3) from atop of enclosure mounting plate (6).
Figure 1. Installation Hardware
0039 00-1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business