TM 10-4110-262-13&P
DIRECT SUPPORT MAINTENANCE
ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
LOW PRESSURE CUTOUT SWITCH
REPLACE
INITIAL SETUP
References
Tools and special tools
PMCS Instruction (WP 0010 00)
Tool Kit, Organizational Maintenance
Refrigeration Unit Service (WP 0031 00)
Equipment Conditions
Materials and Parts
Disconnect ADR-300 from the main power
Switch Low Pressure Cutout
source.
Personnel Required
HVAC Technician (MOS 52C, AFSC 3E1x1) (1)
WARNING
Sharp object. Edges are very sharp to the touch. Be
careful not to cut your hands or limbs. Failure to comply
may cause serious injury to personnel.
REPLACE
1. Remove the condenser section front grille and top grille.
2. Locate the low pressure cut-out switch near the receiver on the suction line (see figure). Cut any wire
ties restraining the switch wires.
3. Disconnect the weather-tight connector on the light switch wires.
CAUTION
Use a backup wrench on the low pressure switch and the schrader valve.
Lines could break causing a leak. Failure to comply may result in
damage to equipment.
4. Unscrew the switch and remove it from the schrader valve.
5. Thread the switch over the schrader valve. Tighten the switch securely.
6. Connect the switch wires to the connector separated in Step 3 above.
7. Secure the wires and connector with wire ties.
0042 00-1
|