Figure 4. Standby Motor Alignment Clearances.
Figure 5. Condenser Fan Installation (Sheet 1 of 2).

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  332    333    334    335    336  337  338    339    340    341    342  
img
TM 10-8145-222-23
0034
REPLACE CONTINUED
11. On MTRCS01, remove four bolts (Figure 5, Sheet 1, Item 4), washers (Figure 5, Item 5), and nuts (Figure 5,
Item 6) securing standby motor (Figure 5, Item 7) to left (Figure 5, Item 8) and right (Figure 5, Item 9) motor
brackets.
NOTE
Note location of two long and two short bolts.
12. On MTRCS02, remove four bolts (Figure 5, Sheet 2, Item 4) and washers (Figure 5, Item 5) securing standby
motor (Figure 5, Item 7) to motor bracket (Figure 5, Item 10.1).
13. Slide standby motor (Figure 5, Item 7) aft enough to gain required room for fan removal.
14. Remove four bolts (Figure 5, Item 10) and four washers (Figure 5, Item 11) securing condenser fan (Figure 5,
Item 12) to fan bushing (Figure 5, Item 13).
15. Carefully separate fan (Figure 5, Item 12) from fan bushing (Figure 5, Item 13).
16. Remove condenser fan (Figure 5, Item 12).
17. Clean and check inside of condenser coil before installing a new fan.
0034-8