TM 10-8145-222-23
0059
REPLACE CONTINUED
WARNING
The refrigeration unit weighs approximately 1,200 pounds and must be removed from
the MTRCS frame mounting location using a forklift.
The forklift operator must be aware of ground personnel positions at all times. A
forklift ground guide must be positioned near the front of the container during removal
of the refrigeration unit.
Always use hearing and head protection when working with or around a forklift. A
forklift engine puts out high noise that can cause serious hearing damage. Many
head injury hazard possibilities exist while using a forklift, such as falling loads and
collision with the forklift itself. Head related injuries can cause serious additional
health hazards or even death to personnel.
31. Position one person on top of the container to make sure electrical cables and piping pass through hole on back
of refrigeration unit chassis when removing.
32. Position forklift tines inside refrigeration unit forklift slots (Figure 13) and carefully provide enough lift to support
refrigeration unit.
Figure 13. Forklift Slots.