Figure 20. Refrigeration Lines.
25. Reconnect evaporator control connector (P8/J8)

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  559    560    561    562    563  564  565    566    567    568    569  
img
.
TM 10-8145-222-23
0059
REPLACE CONTINUED
CAUTION
When reconnecting evaporator connectors 1CP and 2CP, make sure to route them in
such a way as to avoid interference with V-belts during operation.
NOTE
The ground wires for connectors 1CP and 2CP are attached to a single shared
ground with a screw and a nut.
21. Reconnect evaporator electrical connector 2CP (Figure 21, Item 3) and green ground wire (Figure 21, Item 2)
as tagged. Remove tag.
22. Reconnect evaporator electrical connector 1CP (Figure 21, Item 1) and green ground wire (Figure 21, Item 2)
as tagged. Remove tag.
Figure 21. 1CP and 2CP Electrical Connectors.
23. Tie wrap electrical lines as needed to secure to piping and away from V-belt movement.
24. Carefully crawl to roof access point and climb off MTRCS.
0059-23