32. Reconnect 50/60 Hz switch connector (P11/J11)
MAINTAINER MAINTENANCE REFRIGERATION UNIT (MTRC 502 ONLY) REPLACE

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  564    565    566    567    568  569  570    571    572    573    574  
img
. . . . . . . . . .
TM 10-8145-222-23
0059
REPLACE CONTINUED
34. Reconnect microprocessor positive (+) (Figure 26, Item 1), fuel pump positive (+) (Figure 26, Item 2), battery
positive (+) (Figure 26, Item 3), and battery negative (-) (Figure 26, Item 4) cables to studs as tagged. Remove
tag.
Figure 26. Electrical and Fuel Line Connections.
35. Reconnect battery (WP 0053, Reconnect).
36. Charge system with refrigerant (WP 0014, Service).
37. Perform refrigerant leak check (WP 0014, Service).
38. Operate refrigeration unit and check for normal operation (TM 10-8415-222-10, Operating Procedures).
39. Install right-side panel (WP 0013, Install).
40. Install left-side panel (WP 0013, Install).
41. Install front panel assembly (WP 0013, Install).
42. Install top-left panel (WP 0013, Install).
43. Install top-middle panel (WP 0013, Install).
44. Install top-right panel (WP 0013, Install).
45. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE