TM 10-8145-222-23
MAINTAINER MAINTENANCE
MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM (MTRCS)
ACCESS PANELS
REPLACE
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanic Tool Kit
Quartermaster and Chemical Equipment Repairer (2), or
Utilities Equipment Repairer (2)
Service Refrigeration Ordnance
Equipment Condition
Refrigeration unit shut down (TM 10-8145-222-10)
Materials/Parts
REPLACE
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
Remove Top-Left Panel
1. Access top of MTRCS using roof access provided.
2. Rotate four quarter-turn fasteners (Figure 1, Item 1) securing top-left panel (Figure 1, Item 2) counterclockwise
1/4-turn until loose.
3. Remove top-left panel (Figure 1, Item 2) from MTRCS.
Remove Top-Middle Panel
1. Access top of MTRCS using roof access provided.
2. Rotate four quarter-turn fasteners (Figure 1, Item 3) securing top-middle panel (Figure 1, Item 4) counter-
clockwise 1/4-turn until loose.
3. Remove top-middle panel (Figure 1, Item 4) from MTRCS.
Remove Top-Right Panel
1. Access top of MTRCS using roof access provided.
2. Rotate four quarter-turn fasteners (Figure 1, Item 5) securing top-right panel (Figure 1, Item 6) counterclockwise
1/4-turn until loose.
3. Remove top-right panel (Figure 1, Item 6) from MTRCS.
0013-1