TM 10-8145-222-23
0011
PMCS CONTINUED
Table 1. Maintainer Maintenance Preventative Maintenance Checks and Services (PMCS) Continued.
Item
Interval
Item To Be
Procedure
Equipment
No.
Checked or
Not Ready/
Serviced
Available If
9
1500
Clean compartment 1 and compartment 2 evaporator coils
Hours
by removing any debris from coils and rinsing with low
coils not
pressure water.
cleaned.
10
1500
Hours
not cleaned.
11
1500
Fuel Filter
Replace fuel pump filter element (WP 0032, Service).
Fuel pump filter
Hours
element not
replaced.
12
1500
Fuel Tank
Replace fuel tank filler flange/strainer (WP 0058, Repair).
Fuel tank
Hours
Strainer
strainer not
replaced.
13
3000
Belts
Replace V-belts.
All V-belts not
Hours
a. On MTRCS01, Standby Motor to Single-Phase
replaced.
c. Standby Motor to Compressor V-belt (WP 0036,
Replace).
d. Engine to Compressor V-belt (WP 0037, Replace).
14
6000
Cooling System
Drain and flush cooling system (WP 0026, Service).
Cooling system
hours
not drained and
flushed.
15
90 days
Refrigeration
Refrigeration
CAUTION
Unit
unit will not
start.
Do not run refrigeration unit if it is pumped down
for long term storage.
Operate system for a minimum of 15 minutes to keep engine
and refrigeration components lubricated and battery fully
charged (TM 10-8145-222-10, Refrigeration Unit Operation).
END OF WORK PACKAGE
0011-18