• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 8. Alternator V-Belt.
Figure 2. Emergency Stop Switch.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  348    349    350    351    352  353  354    355    356    357    358  
img
. . . . . . . . . . . .
TM 10-8145-222-23
0036
MAINTAINER MAINTENANCE
STANDBY MOTOR TO COMPRESSOR V-BELT
REPLACE, ADJUST
INITIAL SETUP:
Tools and Special Tools
References
Face Shield (WP 0097, Item 20)
TM 10-8415-222-10
Gloves, Rubber (WP 0097, Item 21)
WP 0013
Refrigeration Equipment
WP 0053
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
WP 0091
Service Refrigeration Ordnance
TM 10-8145-222-23P
Tool Kit (WP 0096, Table 2, Item 6)
Equipment Condition
Tester, Belt Tension (TM 10-8415-222-10, Item 5)
Refrigeration unit shut down (TM 10-8415-222-10)
Personnel Required
External power cables disconnected (TM 10-8415-
Utilities Equipment Repairer
222-10)
Top-left panel removed (WP 0013)
Top-middle panel removed (WP 0013)
REPLACE
WARNING
Beware of V-belts and belt driven components. The refrigeration unit may start
automatically. Before performing maintenance on any belt driven system, make sure
that the power to the unit is off.
1. Open control panel access door (Figure 1, Item 1).
2. Place POWER ON/DOWN switch (Figure 1, Item 2) on control panel to DOWN position.
3. Disconnect negative (-) battery terminal (WP 0053, Disconnect).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
4. Access top of MTRCS using roof access.
0036-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.