• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTAINER MAINTENANCE STANDBY MOTOR TO COMPRESSOR V-BELT REPLACE, ADJUST
Figure 3. Standby Motor to Compressor V-Belt.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  349    350    351    352    353  354  355    356    357    358    359  
img
.
TM 10-8145-222-23
0036
Figure 1. POWER ON/DOWN Switch.
REPLACE CONTINUED
5. Place emergency stop switch (Figure 2, Item 1) in PUSH TO STOP position.
Figure 2. Emergency Stop Switch.
6. Remove tensioner adjustment bolt (Figure 3, Item 1) and nut (Figure 3, Item 2) from idler (Figure 3, Item 3) and
bracket (Figure 3, Item 4).
7. Remove lock nut (Figure 3, Item 5) and washer (Figure 3, Item 6) from idler assembly shaft (Figure 3, Item 7).
Discard lock nut.
8. Remove idler (Figure 3, Item 3) and idler pulley (Figure 3, Item 8) from idler assembly shaft (Figure 3, Item 7).
0036-2