TM 10-8145-222-23
MAINTAINER MAINTENANCE
REFRIGERATION UNIT
(MTRCS02 ONLY)
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
TM 10-8415-222-10
Refrigeration Equipment
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
Service Refrigeration Ordnance
TM 10-8145-222-23P
Equipment Condition
Refrigeration unit shut down (TM 10-8415-222-10)
Personnel Required
External power cables disconnected (TM 10-8415-
Utilities Equipment Repairer (2)
222-10)
REPLACE
Remove
1. Recover refrigerant from system (WP 0014, Service).
WARNING
The refrigeration unit can start automatically causing drive components and fans to
operate unannounced. Unit operation must be prevented to avoid personal injury.
2. Disconnect battery (WP 0053, Disconnect). Cut tie wraps so positive and negative cables can be removed and
tucked out of the way with RU.
3. Replace battery cover temporarily.
4. Tag and disconnect fuel pump connector (P1/J1) (Figure 1, Item 1).
5. Tag and disconnect control panel connector (P5/J5) (Figure 1, Item 2).
0060-1