TM 10-8145-222-23
MAINTAINER MAINTENANCE
REFRIGERATION UNIT
SERVICE
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Utilities Equipment Repairer (2)
References
Refrigeration Equipment
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
TM 10-8145-222-10
Service Refrigeration Ordnance
Materials/Parts
Equipment Condition
Refrigeration unit shut down (TM 10-8145-222-10)
SERVICE
WARNING
Sudden and irreversible tissue damage can result from freezing. Wear gloves and
face protector or safety glasses in any situation where skin or eye contact with
refrigerant is possible.
Compressor lubricating oil used in this equipment is caustic. Wear gloves and a face
protector or safety glasses in any situation where skin or eye contact is possible. If oil
does contact skin, wash with soap and water.
Dangerous chemical refrigerant under pressure is used in this equipment. Use great
care to avoid contact with liquid refrigerant. Work in a well ventilated area. Heat may
cause the refrigerant to decompose and release irritating, toxic, and corrosive gases.
Prevent contact of refrigerant with flame or hot surfaces.
NOTE
Refrigeration system repairs must be performed by a technician certified to perform
such duties in accordance with EPA restrictions. Performing repairs without proper
certification may be a violation of public law and subject to severe penalties.
0014-1