TM 10-8145-222-23
0071
REPLACE CONTINUED
37. Connect battery negative (-) terminal (WP 0053, Reconnect).
38. Perform BEFORE operation PMCS checks (TM 10-8415-222-10).
39. Operate diesel engine for sufficient time to check all connections for fuel, oil, and coolant leaks (TM 10-8415-
222-10, Operating Procedures).
41. Shut down refrigeration unit (TM 10-8415-222-10, Operating Procedures).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or even death.
Keep three points of contact on the MTRCS at all times when on the roof.
42. Gain access to top of MTRCS using roof access.
43. Make sure emergency stop switch is in PULL TO START position.
44. Install top-middle panel (WP 0013, Install).
45. Install top-right panel (WP 0013, Install).
46. Exit top of MTRCS.
47. Install right-side panel (WP 0013, Install).
48. Install front panel assembly (WP 0013, Install).
49. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
Alignment
Alignment of the three major refrigeration unit components (diesel engine, compressor, and standby motor) is
important so that the belts interconnecting these components wear evenly. Misalignment of these three components
could cause belt failure and subsequent system shutdown. Diesel engine alignment is accomplished by loosening ten
bolts at the base of the engine in order to adjust the position of the engine.
1. Remove right-side panel (WP 0013, Remove).
2. Remove front panel assembly (WP 0013, Remove).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or even death.
Keep three points of contact on the MTRCS at all times when on the roof.
3. Gain access to top of MTRCS using roof access.
4. Make sure emergency stop switch is in PUSH TO STOP position.
0071-24