REPAIR CONTINUED
23. Install the two ground wires (Figure 16, Item 3) onto the microboard by installing one nut (Figure 16, Item 2) and
washer.
24. Install the six colored wires (Figure 16, Item 1) into the red connector by depressing the connector retainers and
inserting each wire.
25. Put sheet metal panel back in place and secure to the hinged MPC box panel with four hex bolts.
26. Install UFR2 module (Figure 15, Item 3).
27. Install the four outer acorn nuts on the outside of the hinged panel.
28. Close the hinged microprocessor control panel on left side of refrigeration unit and install two bolts to secure.
29. Swing temperature chart recorder back into place and install pin.
30. Reconnect battery terminals.