TM5-4110-234-14
TO 40R7-5-7-1
(2)
Open left side access doors.
b. Removal. (See figure 4-32).
Fig. 4-32. Air Cleaner F10000RG-2
(1)
Remove the wing nut.
(2)
Lift the air cleaner cover and the filter element up and out of the unit.
c. Cleaning.
(1)
Check and clean the air cleaner every 25 hours. Replace it with a new one every 100 hours. Increase
frequency in extreme dusty conditions.
(2)
Clean by tapping the element gently on a flat surface.
Do not run engine with air cleaner removed. Intake of dirty air or solid materials could cause severe
damage to engine parts.
d. Installation.
(1)
Place the filter element and the air cleaner cover on the base.
(2)
Secure with the wing nut finger tight.
(3)
Connect battery if it was disconnected.
(4)
Close access doors.
4-78
|