Table 3-2. Troubleshooting-Continued
3-7, and 3-8).
(paras 3-6, 3-7,
and 3-8).
(paras 3-6, 3-7,
and 3-8).
Section V. FIELD EXPEDIENT REPAIRS
3-13. General
tioner is connected to the power source, the compressor is
Operator and organizational maintenance trouble
defective and must be replaced. Report this condition to
direct support maintenance.
may occur while the air conditioner is operating in
the field where supplies and repair parts are not
available and normal corrective action cannot be
3-15. Compressor Heater Inoperative
performed. When this condition exists, the fol-
lowing expedient repairs may be used in emergen-
Trouble
Expedient Remedy
cies, upon the decision of the unit commander.
Disconnect thermostat from
Compressor heater ther-
Equipment so repaired must be removed from op-
mostat defective.
compressor power recep-
eration as soon as possible and properly repaired
tacle connector and from
before being placed in operation again.
the heater. Connect the
lead directly to the power
receptacle lead. Refer to
3-14. Compressor Inoperative
wiring diagrams.
Trouble
Expedient Remedy
(Compressor overload
Bypass the protector by in-
protector.
Note. If the heater is not activated when the air con-
stalling three insulated
ditioner is connected to the power source, the heater is
jumper wires between the
defective and must be replaced. Report this condition to
connection terminals on the
direct support maintenance.
compressor (para 5-6).