Click here to make tpub.com your Home Page

Page Title: Figure 5-6. Electrical heater thermostat removal and installation.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Figure 5-6. Electrical heater thermostat removal and installation.
c. Repair. Remove insulation to expose 1/2 inch
with electrical tape. Refer to figure 1-4 for prac-
tical wiring diagrams.
of bare wire on each side of break. Twist the wire
ends together and solder the connection. Cover the
connection with electrical tape and friction tape
520. Service Valves
making certain to cover all the exposed area. Re-
a. General. The two angle type service valves
place broken terminal lugs with, exact duplicates.
(suction tube and discharge tube) provide access
d. Replacement. Replace single wire by using
to the refrigerant system.
exact duplicates of terminal lugs from old wire. If
b. Removal. Discharge the refrigerant system
the wire is part of a harness assembly, disconnect
and refer to figure 5-11 and remove the service
the wire at both ends and cap ends. Attach the
valves.
replacement wire to the outside of the harness
AGO 20053A

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business