TM5-4120-347-14
The junction box is located in the upper left front corner of the unit.
a. Removal. (See figure 4-25)
Junction Box
(1) Disconnect power at power source.
(2) See paragraph 4-27a and figure 4-18 and remove the control module.
(3) Remove the top front cover.
(4) Remove seven screws and lock washers and carefully slide the junction box out of the unit.
NOTE
Most maintenance, testing and inspection of the junction box and individual components can be
done at this stage. The junction box should be supported on a stand or table to avoid damage to wire
or connections. If the complete junction box is to be replaced or removed proceed to step (5).
(5) Tag and disconnect the individual wires and connectors of the junction box harness from the unit.
(6) Remove the junction box.