TM 9-4120-425-14&P
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
0016-00
Table 1. Unit Preventive Maintenance Checks and Services (PMCS) - Continued
ITEM TO BE
EQUIPMENT NOT
ITEM
INTERVAL
CHECKED OR
PROCEDURE
READY/AVAILABLE
NO.
SERVICED
IF:
Evaporator Air Intake
6.
Position air filter (5) into louver
Filter and Evaporator
housing (4). Secure filter with clip
Air Intake Louver
(8) inside louver casing.
Continued
7.
Install evaporator air intake louver
(4) with screw (1) and washers (2)
and (3).
2
Weekly
Evaporator Air
1.
Check louver (3) for dirt or damage.
Louver is missing or
Discharge Louver
needs to be replaced.
2.
Clean or replace damaged parts.
3.
Inspect louver for bent blades.
Straighten or replace.
WARNING
Dry cleaning solvent (Item 16, WP
potentially dangerous to personnel
and property. Avoid repeated and
prolonged skin contact. Do not use
near open flame or excessive heat.
Flash point of solvent is 100F
(38C).
Items are damaged,
3
Quarterly
Mist Eliminator
1.
Remove top cover. See WP 0019-00.
missing or clogged.
2.
Slide mist eliminator (1) out of the
mist eliminator holder.
3.
Inspect mist eliminator (1) for
damage. Replace if damaged.
4.
Clean mist eliminator (1).
5.
Install mist eliminator (1) in holder.
0016-00-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |