TM 9-4120-425-14&P
REFRIGERATION SYSTEM SERVICING (LEAK TEST)
THIS WORK PACKAGE COVERS:
Service (Leak Test)
INITIAL SETUP:
Maintenance Level
Direct Support
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0118-00)
Tool Kit, Service, Refrigeration Unit (Item 2, Table 2, WP 0118-00)
Mask, Air Filtering (Item 29, Table 1, WP 0121-00)
Test Equipment
Electronic refrigerant gas leak detector (See TM 9-4940-509-14&P)
Materials/Parts
Nitrogen (Item 4, Table 1, WP 0121-00)
Refrigerant R-22 (Item 10, Table 1, WP 0121-00)
References
Equipment Condition
Main power source disconnected.
WARNING
Disconnect air conditioner power.
WARNING
Be sure that the manifold hoses are correctly connected. BLUE Hose = Low
Pressure, RED Hose = High Pressure.
NOTE
After repair or replacement of a refrigeration component, replace the filter-drier prior
to leak testing. See WP 0066-00.
0052-00-1
|