TM 9-4120-430-14
0014 00
Figure 1. Base Mounting Holes
Grounding
1. Clean front of ground connection to obtain a bright metal surface.
2. Remove insulation from ends of grounding wire (8 AWG) or use bare ends. Make loop at wire ends.
3. Using 1/4-20 nut and washer, attach one end of wire to air conditioner front panel ground stud.
4. Wrap a suitable length of perforated strap around clean surface on water pipe or grounding rod.
5. Using a 1/4-20 screw, two washers and nut, attach other end of grounding wire to strap in a manner such as to
securely tighten strap to pipe or grounding rod, (8 AWG) and wire to strap. If vehicle chassis is used, secure other
end of grounding wire to vehicle chassis using screw, nut, and lockwasher. The screw shall fit in a tapped hole in the
chassis or frame or it shall be held in hole by nut.
WARNING
The vehicle chassis (if used) must be grounded before power is supplied to
the unit.
0014 00-4
|