TM 9-4120-430-14
0053 00
WARNING
Ensure power source is disconnected. Ensure refrigerant
system is discharged.
REMOVAL
1.
Remove screw (1), locknut (2), and receiver clamp (3) which hold receiver (4) onto side bulkhead of unit housing.
2.
Debraze tubing connected to receiver (4) (see WP 0046 00) and remove receiver (4) from unit.
INSTALLATION
1.
Place receiver (4) into unit and loosely install receiver clamp (3) with screw (1) and locknut (2).
2.
Place tubing connections onto receiver (3).
3.
Braze the tube joints (see WP 0046 00).
4.
Tighten hardware installed in step (1).
5.
Replace filter drier (see WP 0051 00).
6.
Install top cover (see WP 0018 00).
7.
Service the refrigeration system (see WP 0047 00 thru WP 0050 00).
Figure 1. Refrigerant Receiver
END OF WORK PACKAGE