TM 9-4120-430-14
DIRECT SUPPORT MAINTENANCE
AIR CONDITIONER, COMPACT, HORIZONTAL
FILTER-DRYER MAINTENANCE
INSPECT, REMOVAL, INSTALLATION
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0067 00)
Tool Kit, Service, Refrigeration Unit (Item 2, WP 0067 00)
Recovery and Recycle Unit, Refrigerant (Item 5, WP 0067 00)
Mask, Air Filtering (Item 29, Table 1, WP 0069 00)
Test Equipment
Electronic refrigerant gas leak detector
Materials/Parts
Nitrogen (Item 4, WP 0069 00)
References
WP 0069 00 (MAC)
Personnel Required
One
Equipment Condition
Main power source is disconnected
Refrigerant system discharged (WP 0044 00)
Special Environmental Condition
WARNING
REFRIGERANT-22 (R-22)
Unit contains R-22, a chemical substance which harms public health and the
environment by destroying ozone in the upper atmosphere, and that the equipment is
to be serviced by qualified personnel only.
Operation of the recovery/recycling unit must be by AUTHORIZED PERSONNEL
ONLY.
INSPECT
Check filter-drier for leaks or damage.
NOTE
The filter-drier must be replaced each time the refrigeration system has been opened. It should
be installed just before unit is leak tested.
0051 00-1
|