TM 10-8145-222-23
0015
REPLACE CONTINUED
6. Remove two screws (Figure 2, Item 2), lock washers (Figure 2, Item 3), washers (Figure 2, Item 4), and nuts
(Figure 2, Item 5) securing emergency stop switch (Figure 2, Item 6) to container frame (Figure 2, Item 7).
Discard lock washers.
7. Remove emergency stop switch (Figure 2, Item 6).
8. Install new emergency stop switch (Figure 2, Item 6) to container frame (Figure 2, Item 7) and secure using two
screws (Figure 2, Item 2), new lock washers (Figure 2, Item 3), washers (Figure 2, Item 4), and nuts (Figure 2,
Item 5).
9. Place emergency stop switch (Figure 2, Item 6) in PULL TO START position.
10. Reconnect emergency stop switch electrical connector (Figure 2, Item 1).
11. Install top-left panel (WP 0013, Install)
12. Climb off roof using roof access provided.
13. Reconnect battery negative (-) terminal (WP 0053, Reconnect).
14. On control panel (Figure 1, Item 1), place POWER ON/DOWN switch (Figure 1, Item 2) to ON position.
15. Start refrigeration unit (TM 10-8145-222-10, Operating Procedures).
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
16. Access top of MTRCS using roof access provided.
WARNING
The exhaust system will become extremely hot after a short period of operating time.
Allow engine to cool for 30-minutes before performing maintenance.
17. Place emergency stop switch (Figure 2, Item 6) in PUSH TO STOP position and verify refrigeration unit shuts
down.
18. Place emergency stop switch (Figure 2, Item 6) in PULL TO START position.
19. Climb off roof using roof access provided.
20. Place MTRCS back into desired mode of operation (TM 10-8145-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0015-3/4 blank