REPLACE ­ CONTINUED
Check Compressor Oil Level

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  213    214    215    216    217  218  219    220    221    222    223  
img
. . . . . . . . . . . . .
TM 10-8145-222-23
0016
MAINTAINER MAINTENANCE
COMPRESSOR
SERVICE
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Face Shield (WP 0097, Item 20)
Utilities Equipment Repairer
Gloves, Rubber (WP 0097, Item 21)
References
Refrigeration Equipment
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
TM 10-8145-222-10
Service Refrigeration Ordnance
WP 0013
Tool Kit (WP 0096, Table 2, Item 6)
WP 0014
WP 0045
Materials/Parts
WP 0061
Oil Charge, 8 pints (WP 0097, Item 29)
Equipment Condition
Tubing, four feet, cut to length (WP 0097, Item 53)
Refrigeration unit shut down (TM 10-8145-222-10)
Top-middle panel removed (WP 0013)
Top-left panel removed (WP 0013)
SERVICE
Perform the following tasks to properly service the compressor. This work package will provide instructions for
checking compressor oil level, adding oil to an in-system compressor and new compressor, and for removing oil from
a compressor that has been over-serviced.
WARNING
Sudden and irreversible tissue damage can result from freezing. Wear gloves and
face protector or safety glasses in any situation where skin or eye contact with
refrigerant is possible.
Compressor lubricating oil used in this equipment is caustic. Wear gloves and a face
protector or safety glasses in any situation where skin or eye contact is possible. If oil
does contact skin, wash with soap and water.
Dangerous chemical refrigerant under pressure is used in this equipment. Use great
care to avoid contact with liquid refrigerant. Work in a well ventilated area. Heat may
cause the refrigerant to decompose and release irritating, toxic, and corrosive gases.
Prevent contact of refrigerant with flame or hot surfaces.
NOTE
Refrigeration system repairs must be performed by a technician certified to perform
such duties in accordance with EPA restrictions. Performing repairs without proper
certification may be a violation of public law and subject to severe penalties.