NOTE
The V-belt tension is determined by reading the scale at the exact location where the
black indicator arm intersects the scale on top of the gauge.
10. Turn tension gauge (Figure 6, Item 1) so that scale (Figure 6, Item 5) can be read, and determine V-belt
tension.
11. Adjust V-belt tension as needed to obtain required tension per this WP.
12. Recheck V-belt tension per steps 6-10 of this task.
13. Install top-middle panel (WP 0013, Install).
14. Place emergency stop switch (Figure 2, Item 1) in PULL TO START position.
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
15. Exit top of MTRCS using roof access provided.
16. Reconnect negative (-) battery terminal (WP 0053, Disconnect).
17. Place POWER ON/DOWN switch (Figure 1, Item 2) to ON position.
18. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).