REPLACE ­ CONTINUED
Figure 1. POWER ON/DOWN Switch.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  378    379    380    381    382  383  384    385    386    387    388  
img
. . . . . . .
TM 10-8145-222-23
0039
MAINTAINER MAINTENANCE
MUFFLER
REPAIR, REPLACE
INITIAL SETUP:
Tools and Special Tools
References
General Mechanic Tool Kit (WP 0096, Table 2, Item 5)
TM 10-8415-222-10
WP 0013
Materials/Parts
WP 0053
WP 0091
Penetrating Oil (WP 0097, Item 36)
TM 10-8145-222-23P
Personnel Required
Equipment Condition
Quartermaster and Chemical Equipment Repairer
Refrigeration unit shut down and cool (TM 10-8415-
222-10)
External power cables disconnected (TM 10-8415-
222-10)
REPAIR
Muffler repair is limited to the replacement of missing or damaged rain cap.
1. Open control panel access door (Figure 1, Item 1).
2. Place POWER ON/DOWN switch (Figure 1, Item 2) on control panel to DOWN position.
WARNING
The exhaust system will become extremely hot after a short period of operating time.
Allow engine to cool for 30-minutes before performing maintenance.
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
3. Access top of MTRCS using roof access.