24. Reconnect electrical wiring (Figure 4, Item 13) to heater (Figure 4, Item 16) as tagged by splicing wires
together.
25. Secure any loose wiring and connectors as needed inside evaporator compartment using tie wraps (Figure 4,
Item 4).
26. Remove tags from electrical wiring.
27. Feed drain tube heaters through evaporator drip pan (Figure 4, Item 12).
28. Install drip pan (Figure 4, Item 12) to evaporator (Figure 4, Item 7) and secure using three bolts (Figure 4,
Item 10) and three washers (Figure 4, Item 11).
29. Install front evaporator cover (Figure 4, Item 8) to evaporator (Figure 4, Item 7) and secure using eight bolts
(Figure 4, Item 9).
30. Install evaporator cover panel (Figure 4, Item 1) onto front evaporator cover (Figure 4, Item 8) hinged area.
31. Feed drain tube heaters through two elbows (Figure 4, Item 20) and install elbows to evaporator (Figure 4,
Item 7).
32. Feed drain tube heaters into drain tube (Figure 4, Item 19) and secure drain tubes to evaporator (Figure 4,
Item 7).
33. Route temperature chart recorder sensor (Figure 4, Item 6) and return air sensor (Figure 4, Item 5) wiring
34. Mount return air sensor (Figure 4, Item 5) and temperature chart recorder sensor (Figure 4, Item 6) to cover and
secure with two tie wraps (Figure 4, Item 4).
35. Close evaporator cover panel (Figure 4, Item 1) by installing two bolts (Figure 4, Item 2), two washers (Figure 4,
Item 3) and two new lock washers (Figure 4, Item 18).
WARNING
MTRCS doors are very heavy and solid objects. Make sure that doors are secured to
the frame of the container when open. Wind gusts can be strong enough to slam the
doors shut with great force causing serious injury or death to personnel.
36. Close MTRCS rear and side access doors after making sure no personnel are remaining inside (TM 10-8415-
222-10, Loading).
37. Reconnect battery negative (-) terminal (WP 0053, Reconnect).
0046-5