Figure 4. Removal/Installation of Battery.
MAINTAINER MAINTENANCE BATTERY JUMP START

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  487    488    489    490    491  492  493    494    495    496    497  
img
TM 10-8145-222-23
0053
REPLACE CONTINUED
Install
1. Install replacement battery (Figure 4, Item 1) in battery box (Figure 4, Item 2).
WARNING
Storage batteries contain a high current potential and can explode if short circuited.
Never allow any metal to cross between the battery terminals or between the positive
terminal and any part of the MTRCS frame. Personal injury could result.
2. Connect positive (+) battery lead (Figure 4, Item 4) to positive (+) battery terminal. Tighten lead.
3. Connect negative (-) battery lead (Figure 4, Item 5) to negative (-) battery terminal. Tighten lead.
4. Install battery box cover (Figure 4, Item 6) on battery box (Figure 4, Item 2).
5. Install battery box clamp (Figure 4, Item 10) over cover (Figure 4, Item 6).
6. Install two L-bolts (Figure 4, Item 9) through lip on battery pan (Figure 4, Item 3) and through battery box clamp
(Figure 4, Item 10).
7. Secure two L-bolts (Figure 4, Item 9) to battery box clamp (Figure 4, Item 10) using two lock nuts (Figure 4,
Item 7) and flat washers (Figure 4, Item 8).
8. Tighten lock nuts (Figure 4, Item 7) hand tight.
9. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0053-10