• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 7. Changing Cartridge Pen Arm.
Figure 1. Document Holder.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  503    504    505    506    507  508  509    510    511    512    513  
img
. . . . . . . .
TM 10-8145-222-23
0056
MAINTAINER MAINTENANCE
DOCUMENT HOLDER
REPLACE, REPAIR
INITIAL SETUP:
Tools and Special Tools
Personnel Required
SATS (WP 0096, Table 2, Item 8)
Quartermaster and Chemical Equipment Repairer
Shield, Face (WP 0097, Item 20)
References
Materials/Parts
WP 0091
Adhesive (WP 0097, Item 1)
TM 10-8145-222-23P
Alcohol, Isopropyl (WP 0097, Item 2)
Gloves, Rubber (WP 0097, Item 21)
Blind Rivet, (0.187 shank diameter x 0.25 grip length)
(WP 0111, Item 9)
REPLACE
1. Remove contents of document holder and set aside.
2. Remove three bolts (Figure 1, Item 1), lock washers (Figure 1, Item 2), and washers (Figure 1, Item 3) securing
document holder (Figure 1, Item 4) to MTRCS frame. Discard lock washers.
3. Remove document holder (Figure 1, Item 4).
4. Install new document holder (Figure 1, Item 4) to MTRCS frame and secure using three bolts (Figure 1, Item 1),
new lock washers (Figure 1, Item 2), and washers (Figure 1, Item 3).
5. Tighten bolts (Figure 1, Item 1) (WP 0091).
6. Replace contents of document holder.
0056-1


Privacy Statement