Figure 14. Radiator Cap.
Figure 16. Electrical Cable Feeds.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  581    582    583    584    585  586  587    588    589    590    591  
img
.
TM 10-8145-222-23
0060
REPLACE CONTINUED
WARNING
Installation of the refrigeration unit from the MTRCS is accomplished using a forklift.
Only authorized licensed forklift operators are allowed to drive a forklift. The forklift
operator must be aware of ground personnel at all times. Personnel can be crushed
causing serious injury or death.
Always use hearing and head protection when working with or around a forklift. A
forklift engine puts out high noise that can cause serious hearing damage. Many
head injury hazard possibilities exist while using a forklift, such as falling loads and
collision with the forklift itself. Head related injuries can cause serious additional
health hazards or even death to personnel.
3. Position forklift tines inside refrigeration unit forklift slots (Figure 15) and carefully lift refrigeration unit into
position for installation onto MTRCS chassis.
Figure 15. Forklift Slots.
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
4. Position one person on top of container to make sure cables and piping pass through hole on back of
refrigeration unit when installing.
5. Position forklift, with refrigeration unit lifted, in front of MTRCS frame.
6. Remove pin and swing chart recorder out of the way.