TM 10-8145-222-23
0066
REPLACE CONTINUED
CAUTION
The suction tube can kink or be easily bent if not careful. Use care when removing
suction service valve from suction tube so that tube is not bent or otherwise damaged
during removal.
6. Remove two bolts (Figure 1, Item 1), washers (Figure 1, Item 2), and nuts (Figure 1, Item 3) securing suction
tube saddle clamp and spacer (Figure 1, Item 4) located near CPR valve (Figure 1, Item 5).
Figure 1. Suction Service Valve Assembly Removal.