MAINTAINER MAINTENANCE SUCTION SERVICE VALVE REPLACE
Rear side of saddle clamp will stay in place until both saddle clamps have been removed

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  631    632    633    634    635  636  637    638    639    640    641  
img
.
TM 10-8145-222-23
0066
REPLACE CONTINUED
CAUTION
The suction tube can kink or be easily bent if not careful. Use care when removing
suction service valve from suction tube so that tube is not bent or otherwise damaged
during removal.
6. Remove two bolts (Figure 1, Item 1), washers (Figure 1, Item 2), and nuts (Figure 1, Item 3) securing suction
tube saddle clamp and spacer (Figure 1, Item 4) located near CPR valve (Figure 1, Item 5).
Figure 1. Suction Service Valve Assembly Removal.