Figure 2. Support Arm.
Figure 4. Suction Service Valve Assembly (Standalone).

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  634    635    636    637    638  639  640    641    642    643    644  
img
.
TM 10-8145-222-23
0066
REPLACE CONTINUED
NOTE
The accumulator will need to be loosened from its mounting position in order to gain
the needed movement in the tubing to be de-soldered so that the joint can be
separated. The entire accumulator will not have to be removed, just the mounting
hardware securing it to the refrigeration unit chassis.
17. Remove mounting nut (Figure 3, Item 1) and washer (Figure 3, Item 2) from bottom of accumulator to facilitate
separation of tubes during desoldering operation.
18. Disconnect copper line (Figure 3, Item 4) running from filter-drier (Figure 3, Item 5) to accumulator (Figure 3,
Item 3) at filter-drier only.
Figure 3. Accumulator Mounting Removal.