Figure 5. Suction Service Valve Assembly Installation.
MAINTAINER MAINTENANCE RECEIVER AND CHECK VALVES REPLACE

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  638    639    640    641    642  643  644    645    646    647    648  
img
. . . . . . . . . .
TM 10-8145-222-23
0066
REPLACE CONTINUED
36. Install support arm (Figure 3, Item 1) and support arm bracket (Figure 3 Item 7) and secure using four bolts
(Figure 3, Item 2) and four washers (Figure 3, Item 3), and two nuts (Figure 3, Item 4), two washers (Figure 3,
Item 5), and two bolts (Figure 3, Item 6).
37. Reinstall partially removed alternator (WP 0030) with wiring connected and secure with alternator.
38. Install and adjust alternator V-belt (WP 0030).
39. Change filter-drier (WP 0018, Replace).
40. Perform evacuation and dehydration (WP 0014, Service).
41. Release refrigerant into system (WP 0014, Service).
42. Perform refrigerant leak check (WP 0014, Service).
43. Install any remaining insulation.
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
44. Install top-middle panel (WP 0013, Install).
45. Install top-left panel (WP 0013, Install).
46. Reconnect battery negative (-) terminal (WP 0053, Reconnect).
47. Run refrigerator unit (TM 10-8415-222-10, Operating Procedures).
48. Check refrigerant level and charge system with refrigerant as required (WP 0014, Service).
49. Verify unit is operating properly.
50. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0066-9/10 blank