Figure 1. Standby Motor Electrical Connection.
Alternator Installation Diagram

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  717    718    719    720    721  722  723    724    725    726    727  
img
. . .
TM 10-8145-222-23
0076
REPLACE CONTINUED
4. Remove standby motor to compressor V-belt (WP 0036, Remove).
5. Remove standby motor to single-phase alternator V-belt (WP 0035, Remove).
NOTE
In order to gain access for removal of standby motor, it will be necessary to position
the alternator located at the pulley end of the standby motor out of the way.
6. Tag and disconnect wire leads (Figure 2, Item 1) and ground wire (Figure 2, Item 2) from alternator (Figure 2,
Item 3) and loosen strain relief; then, pull ground wire (Figure 2, Item 2) so that it does not catch when standby
motor/single-phase alternator assembly is lifted.
7. Remove alternator (WP 0030, Removal).
8. Swing alternator (Figure 2, Item 3) away from standby motor (Figure 2, Item 7) and secure to frame of container
using a tie wrap.
9. Remove one bolt (Figure 2, Item 4), washer (Figure 2, Item 5), and nut (Figure 2, Item 6) securing alternator
brackets (Figure 2, Item 8 and Item 9) to bracket mount on standby motor (Figure 2, Item 10).
10. Remove alternator bracket (Figure 2, Item 9) if necessary for additional clearance. Retain for reinstallation.
11. Remove two screws (Figure 1, Item 6) and washers (Figure 1, Item 7) securing fan shroud (Figure 1, Item 8) to
radiator (Figure 1, Item 9).
12. Remove fan shroud (Figure 1, Item 8). Retain for reinstallation.