TM 10-8145-222-23
MAINTAINER MAINTENANCE
STANDBY MOTOR/SINGLE-PHASE ALTERNATOR
(MTRCS01 ONLY)
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
TM 10-8415-222-10
Service Refrigeration Ordnance
Materials/Parts
Lock Washer (12mm ID) (WP 0111, Item 6)
TM 10-8145-222-23P
Equipment Condition
Personnel Required
External electrical power disconnected (TM 10-8415-
Utilities Equipment Repairer (2)
222-10)
REPLACE
Remove
NOTE
In order to remove and replace the single-phase alternator, the standby motor has to
be removed first to gain access to component. This procedure provides instruction on
removing the standby motor and single-phase alternator as one complete assembly.
After the assembly is removed from the MTRCS, the standby motor and the single-
phase alternator can be separated and replaced individually.
1. Remove four screws (Figure 1, Item 1) and washers (Figure 1, Item 2) securing standby motor electrical wiring
cover (Figure 1, Item 3) to standby motor (Figure 1, Item 4).
2. Remove cover (Figure 1, Item 3) from standby motor (Figure 1, Item 4).
3. Tag and disconnect electrical wiring (Figure 1, Item 5) from standby motor (Figure 1, Item 4).
0076-1