TM 10-8145-222-23
0080
REPLACE CONTINUED
Install
NOTE
Installation of compartment 1 (forward) and compartment 2 (aft) evaporators is nearly
identical. The following installation procedure is applicable to both compartment
evaporators. Any differences in the procedure will be annotated in the text where
applicable.
1. Clean each pipe connection to be soldered on replacement evaporator and on container refrigerant piping
connections.
CAUTION
Use wet rags on either side of soldering points in order to dissipate heat. Use a
reflective plate (stainless steel) behind fittings when soldering in order to protect walls
from heat. Failure to observe precautions can cause equipment damage.
2. Solder a 3/8-inch coupling to container 3/8-inch refrigerant pipe stubout (Figure 6, Item 2) on wall.
3. Solder a 1/2-inch coupling to container 1/2-inch refrigerant pipe stubout (Figure 6, Item 1) on wall.
4. Solder a 7/8-inch coupling to container 7/8-inch refrigerant pipe stubout (Figure 7, Item 2) on wall.
0080-9