Figure 19. Removing Wires on Transformer Terminal Block.
7. Secure transformer (Figure 16, Item 2) to power box (Figure 17, Item 4)

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  882    883    884    885    886  887  888    889    890    891    892  
img
.
TM 10-8145-222-23
0084
REPAIR CONTINUED
26. Remove U-nuts (Figure 20, Item 1) from transformer mounting bracket (Figure 20, Item 2). Retain for
reinstallation.
Figure 20. Transformer U-Nuts.
27. Lower transformer to bench.
28. Close power box door.
Install
1. Position lifting strap on bench and lay transformer, wire side down, over strap so that strap is around middle of
transformer.
2. Open power box door (Figure 14, Item 1) as far as possible and support door open using one soldier/personnel
(Figure 14, Item 2).
3. Lift transformer (Figure 19, Item 2) and position top of transformer with top of power box just above box
(Figure 19).
4. Install four U-nuts (Figure 20, Item 1) on transformer mounting bracket (Figure 20, Item 2).
5. Connect wires to terminal block (Figure 19, Item 1) on top of transformer (Figure 19, Item 2) as tagged. Remove
tags.
6. Slowly lower transformer (Figure 16, Item 2) into power box by guiding it around wires coming out of bottom of
power box.