Figure 3. Battery Cables.
MAINTAINER MAINTENANCE BATTERY BOX (MTRC S02 ONLY) REPLACE, REPAIR

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  895    896    897    898    899  900  901    902    903    904    905  
img
.
TM 10-8145-222-23
0086
REPAIR CONTINUED
12. Install negative (-) battery cable (Figure 3, Item 1) and secure negative (-) battery terminal lug (Figure 3, Item 6)
to refrigeration unit frame using one washer (Figure 3, Item 9) and nut (Figure 3, Item 8).
13. Install opposite end of positive (+) battery cable (Figure 3, Item 2) to battery (Figure 3, Item 4) at battery positive
(+) terminal (Figure 3, Item 5).
14. Install opposite end of negative (-) battery cable (Figure 3, Item 1) to battery (Figure 3, Item 4) at battery
negative (-) terminal (Figure 3, Item 3).
15. Install tie wraps as required to secure battery cables (Figure 3, Item 1 and Item 2).
16. Install access cover (Figure 2, Item 4) to right-side panel (Figure 2, Item 5) and secure using seven screws
(Figure 2, Item 1), new lock washers (Figure 2, Item 2), and washers (Figure 2, Item 3).
17. Install battery box cover (WP 0053, Install).
18. Operate refrigeration unit in accordance with normal operating procedures to verify proper operation after
replacement of battery cables (TM 10-8415-222-10, Operating Procedures).
19. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0086-4